  • Soczewka HRX VIT ACS (VHRXVITACS ) autoklaw

Код товара : VHRXVITACS

Without self stabilizing contact - PART #VHRXVITACS Najszersze widzenie oraz wolny od zniekształceń obraz siatkówki w porównaniu z innymi soczewkami.

Kolor/Wzór
Товар отсутствует
0
Введите адрес e-mail
Высылка в течение по запросу
Цена доставки Отсутствует
Наличие на складе na zamówienie
Pełna oferta Volk Optical USA

Standard

Primary Application - Far-Peripheral Indirect Vitreoretinal Procedures

  • High index glass delivers widest field, distortion free retinal views of any surgical lens
  • Small profile ring facilitates instrument manipulation and surgical procedures
  • Available in standard and patented self stabilizing contact (SSV¨) options
  • Ideal for retinal detachments and giant retinal tears
Field of View Image Magnification
130° / 150° 0.43x

 Without self stabilizing contact - PART #VHRXVIT

With self stabilizing contact - PART #VHRXVITSSV

ACS

Primary Application – Widest Field Views for Vitreoretinal Procedures

  • Superior high index glass design ensures widest field views of any vitrectomy lens
  • Advanced aspheric design provides unmatched high resolution imaging
  • Steam sterilizable for reduced processing time
Field of View Image Magnification
130° / 150° 0.43x

 

Without self stabilizing contact - PART #VHRXVITACS

With self stabilizing contact - PART #VHRXVITSSVACS

Информация по технике безопасности

INDIRECT VITRECTOMY CONTACT (ACS) LENSES:

Do not use a microfiber cloth, as over time these tend to collect dirt and dust which can damage the anti reflective coating on the lens.

Never use a device that shows any sign(s) of damage.

Failure to follow the point-of-use processing steps could adversely affect further decontamination steps.

Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established.

A thorough, manual cleaning process is recommended. Corrosive cleaning agents (i.e. acids, alkalines, etc) are not recommended. Detergent cleaning agents with neutral ph are recommended.

Do not use detergents that contain any type of emollients.

Wiping the lens with a microfiber cloth will cause lens damage. Be sure to use only a soft, lint-free
cotton cloth.

Ensure the device is completely submerged in the disintectant solution for the entirity of the recommended or desired soak time. Do not allow the device to become unsubmerged from the disinfectant solution.

Colored rings may discolor when exposed to Sodium Hypochlorite or Glutaraldehyde. To avoid further degradation please follow only the disinfection procedures indicated for these products in instruction. This color change is purely cosmetic and will not affect the function of the lens.

Do not brush lens portion to avoid scratching. Use a soft, cotton cloth.

To avoid surface damage to contact lenses, NEVER clean the contact elements with alcohol, peroxide or acetone.

Do not use the lens when the contacting surface(s) show(s) any signs of damage.

Do not attempt to use the lens unless an adequate type and amount of coupling fluid is present between the cornea and the contacting lens surface.

Care should be taken to avoid excessive pressure on the cornea as it may affect aqueous dynamics.
Do not attempt to use the lens if, for any reason, the retinal image is unclear or unfocused.
Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established.

Undue tightening of the threaded imaging lens assembly can damage your volk vitrectomy acs® lens.

Fou use by trained personnel only.