  • Soczewka Trans Equator (VTE)

The Symbol : VTE

With Flange - PART #VTE Field of View up to the mid-peripheral retina,Ideal for both PRP and grid laser treatments, Visualize and treat mid-peripheral retinal tears, holes as well as central retinal defects

Kolor/Wzór
4200.00
opak To the virus Vault
The quantity in the package 1 opak
Shipping within 2 dni
Shipping price The Lack Of
The Availability Of dostępny

Zamówienie telefoniczne: 22 651 82 85

With Flange - PART #VTE

The TransEquator is a perfect choice for treating retinal abnormalities in the mid-peripheral to the central retinal region, similar to the Rodenstock Pan Fundus lens. This field of view allows visualization of those defects which are neither too peripheral nor central and lie mid-way to the periphery. The 0.70x magnification enables high detail examination and visualization of the retina for precise and accurate laser spot placement.  Thus, this lens makes for a great combination lens whether you are performing PRP laser treatments or centrally targeted grid laser treatments.

  • Field of View up to the mid-peripheral retina
  • Ideal for both PRP and grid laser treatments
  • Visualize and treat mid-peripheral retinal tears, holes as well as central retinal defects
  • Available in Flange, no Flange and ANF+ contact options

 

 Field of View Image Magnification Laser Spot Magnification
110°/132° 0.70x 1.44x

Safety Information

INDIRECT CONTACT LASER LENSES:

Do not use a microfiber cloth, as over time these tend to collect dirt and dust which can damage the anti reflective coating on the lens.

Never use a device that shows any sign(s) of damage.

Failure to follow the point-of-use processing steps could adversely affect further decontamination steps.

Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established.

A thorough, manual cleaning process is recommended. Corrosive cleaning agents (i.e. acids, alkalines, etc) are not recommended. Detergent cleaning agents with neutral ph are recommended.

Do not use detergents that contain any type of emollients.

Wiping the lens with a microfiber cloth will cause lens damage. Be sure to use only a soft, lint-free
cotton cloth.

Extended exposure and/or exposure to higher concentrations of sodium hypochlorite will result in accelerated degradation of the product.

Colored rings may discolor when exposed to Sodium Hypochlorite or Glutaraldehyde. To avoid further degradation please follow only the disinfection procedures indicated for these products in instruction. This color change is purely cosmetic and will not affect the function of the lens.

Do not brush lens portion to avoid scratching. Use a soft, cotton cloth.

Do not use the lens when the contacting surface(s) show(s) any signs of damage.

Do not attempt to use the lens unless an adequate type and amount of coupling fluid is present between the cornea and the contacting lens surface.

To avoid surface damage to contact lenses, NEVER clean the contact elements with alcohol, peroxide or acetone.

To avoid product damage, never autoclave or boil lenses or adapters.

For use by trained personnel only.