- Categories
-
Soczewka Quadr Aspheric ( VQFLNL )
Shipping within | 7 dni |
Shipping price | The Lack Of |
The Availability Of | na zamówienie 1 opak |
Pełna oferta Volk Optical USA | |
The bar code | |
EAN |
Without Flange - PART #VQFLNF
With a 144° field of view, this lens enables wide field visualization up to the peripheral retina for diagnosis and treatment of peripheral retinal defects. This lens is specially designed to provide wide field visualization even through small pupils. This application is critical when evaluating and treating patients such as those at risk of angle closure, neovascularization of the iris etc. in whom dilation should be avoided. The small pupil capability is also advantageous when treating geriatric populations in whom pupil response to dilation is limited. The large flange on this lens provides the perfect stability and control over the eye needed during laser procedures
- Wide-field distortion free viewing of the retina
- Small-pupil capability
- Ideal for detecting and treating mid to peripheral retinal abnormalities
Field of View |
Image Magnification | Laser Spot Magnification |
120°/144° | 0.51x | 1.97x |
Safety Information
INDIRECT CONTACT LASER LENSES:
Do not use a microfiber cloth, as over time these tend to collect dirt and dust which can damage the anti reflective coating on the lens.
Never use a device that shows any sign(s) of damage.
Failure to follow the point-of-use processing steps could adversely affect further decontamination steps.
Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established.
A thorough, manual cleaning process is recommended. Corrosive cleaning agents (i.e. acids, alkalines, etc) are not recommended. Detergent cleaning agents with neutral ph are recommended.
Do not use detergents that contain any type of emollients.
Wiping the lens with a microfiber cloth will cause lens damage. Be sure to use only a soft, lint-free
cotton cloth.
Extended exposure and/or exposure to higher concentrations of sodium hypochlorite will result in accelerated degradation of the product.
Colored rings may discolor when exposed to Sodium Hypochlorite or Glutaraldehyde. To avoid further degradation please follow only the disinfection procedures indicated for these products in instruction. This color change is purely cosmetic and will not affect the function of the lens.
Do not brush lens portion to avoid scratching. Use a soft, cotton cloth.
Do not use the lens when the contacting surface(s) show(s) any signs of damage.
Do not attempt to use the lens unless an adequate type and amount of coupling fluid is present between the cornea and the contacting lens surface.
To avoid surface damage to contact lenses, NEVER clean the contact elements with alcohol, peroxide or acetone.
To avoid product damage, never autoclave or boil lenses or adapters.
For use by trained personnel only.
Manufacturer details
Volk Optical INC.
7893 Enterprise Dr, Mentor
OH 44060 Mentor,
United States
+1 440-942-6161
volk@volk.com
Responsible person
Rudolf Riester GmbH
Bruckstrasse, 31
72417 Jungingen
Germany
+49747792700
pfister@riester.de