• Категории
  • Soczewka HR Centralis (VHRC)

Код товара : VHRC

This lens gives detailed, high magnification views of the posterior pole for performing focal/Grid Laser procedures.

Kolor/Wzór
Товар отсутствует
0
Количество в упаковке 1 Упаковка
Высылка в течение 2 dni
Цена доставки Отсутствует
Наличие на складе na zamówienie
Pełna oferta Volk Optical USA

PART #VHRC

This lens gives detailed, high magnification views of the posterior pole for performing focal/Grid Laser procedures. Building on the optical capabilities of the Area Centralis, the H-R Centralis is enhanced with small pupil capabilities and fabricated using a high grade, low dispersion glass offering high resolution views of the posterior pole.

  • High magnification for detailed examination and precise treatment of the posterior pole
  • Ideal for focal/grid laser therapy
  • Small pupil capability

 

 Field of View
Image Magnification Laser Spot Magnification
74°/ 88° 1.08x 0.93x


Информация по технике безопасности

INDIRECT CONTACT LASER LENSES:

Do not use a microfiber cloth, as over time these tend to collect dirt and dust which can damage the anti reflective coating on the lens.

Never use a device that shows any sign(s) of damage.

Failure to follow the point-of-use processing steps could adversely affect further decontamination steps.

Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established.

A thorough, manual cleaning process is recommended. Corrosive cleaning agents (i.e. acids, alkalines, etc) are not recommended. Detergent cleaning agents with neutral ph are recommended.

Do not use detergents that contain any type of emollients.

Wiping the lens with a microfiber cloth will cause lens damage. Be sure to use only a soft, lint-free
cotton cloth.

Extended exposure and/or exposure to higher concentrations of sodium hypochlorite will result in accelerated degradation of the product.

Colored rings may discolor when exposed to Sodium Hypochlorite or Glutaraldehyde. To avoid further degradation please follow only the disinfection procedures indicated for these products in instruction. This color change is purely cosmetic and will not affect the function of the lens.

Do not brush lens portion to avoid scratching. Use a soft, cotton cloth.

Do not use the lens when the contacting surface(s) show(s) any signs of damage.

Do not attempt to use the lens unless an adequate type and amount of coupling fluid is present between the cornea and the contacting lens surface.

To avoid surface damage to contact lenses, NEVER clean the contact elements with alcohol, peroxide or acetone.

To avoid product damage, never autoclave or boil lenses or adapters.

For use by trained personnel only.

Сведения о производителе

Volk Optical INC.
7893 Enterprise Dr, Mentor
OH 44060 Mentor,
United States

+1 440-942-6161
volk@volk.com

Ответственное лицо

Rudolf Riester GmbH
Bruckstrasse, 31
72417 Jungingen
Germany

+49747792700
pfister@riester.de

Подпись